Import entire WINTEK legacy directory contents under WINTEK/ subdirectory

- All original files from the WINTEK project (assemblers, libraries, executables, sources from 1995 era) placed under WINTEK/
- Preserved root README.md from initial commit
This commit is contained in:
2026-06-12 14:15:27 -05:00
parent cb09565171
commit 9f8893102d
26 changed files with 918 additions and 0 deletions
+47
View File
@@ -0,0 +1,47 @@
NAM clrio
TTL 'I/O Initialization Routines'
INCL 'IOloc.h'
STL 'ACIA Initialization'
PSCT
GLOBAL cleario,.clrio
EXTERN .LINK
*** cleario, .clrio - reset the ACIA
*
* This routine master resets the 6809 Control Module's ACIA.
* It has a C entry point and an assembler entry point.
**
** C calling sequence: cleario();
**
** Assembler calling sequence:
**
** JSR .clrio
cleario SUBA #0 (C entry point)
BEQ .clrio
JSR .LINK
* We store a 3 into the ACIA control register to perform the
* master reset.
.clrio LDB #$03 (Assembler entry point)
STB ACIA1CR
* The constant 15 (hex) sets-up the ACIA for 8 bits, no parity, 1
* stop bits, divide by 16 (clock rate), with RTS = 0 and Tx
* interrupts inhibited.
LDB #$15
STB ACIA1CR 8+N+1, 1/16, RTS true
* We return an "int" zero as the default returned value in C.
* Note that the 'Z' bit is set properly. Since there are no
* parameters we can use an RTS to return.
CLRD return (int) 0 with 'Z' bit set,
RTS
END